Sherlock 3CG+™  Tip Confirmation System

Sherlock.png
Loading
Overview

The Sherlock 3CG+™ Tip Confirmation System (TCS) is BD's next generation, fully integrated magnetic tracking and ECG-based peripherally inserted central catheter (PICC) tip confirmation technology.

Features

Simultaneous View of Catheter Tip Tracking and ECG

Catheter tip tracking and ECG confirmation are integrated on the same graphical display.

Static ECG baseline

Provides comparative ECG waveform for interpretation of P-wave changes and to assist in maximum P-wave identification.

Dynamic ECG waveform

Measures changes in P-wave morphology to allow the clinician to position the catheter tip  in proximity to the cavoatrial junction.

Ability to maintain sterile field

Through-drape connection allows clinician to maintain maximal barrier sterile field during placement. Probe and wireless remote allow the clinician to maintain sterility while interfacing with Sherlock 3CG+™ TCS.

Tip Confirmation documentation

Allows for PICC tip location to be easily documented in patient's chart or stored on the Sherlock 3CG+™ TCS System.

Guideline Compliance

By helping to position the PICC tip in proximity to the cavoatrial junction, the Sherlock 3CG+™ TCS System helps clinicians comply with AVA and INS guidelines for proper PICC placement.

Benefits

Indicated for use as an alternative method to chest X-ray and fluoroscopy for PICC tip placement confirmation in adult patients.

Immediate confirmation of PICC tip position at the bedside and immediate release of the PICC line.

Increases placement efficiency and reduces catheter manipulations as compared to "blind" catheter placements.

Eliminates costs associated with confirmatory chest X-ray and time previously spent waiting for X-ray confirmation readings.

Eliminates confirmatory chest X-ray exposure to the patient and clinician.

Clinical Study

Sherlock 3CG+™ Tip Confirmation System (TCS) Clinical Study
Getting to the heart of the matter…
Sherlock 3CG+™ Tip Confirmation System (TCS) Clinical Study

Using x-ray to confirm PICC tip placement wastes clinical care time, exposes patients to harmful radiation, and delays medical therapy. The Sherlock 3CG+® Tip Confirmation System (TCS) gets to the heart of this problem by using an adult patient's cardiac electrical activity to position the tip of the PICC in close proximity to the cavoatrial junction (CAJ). Final tip location is confirmed by the nurse at the bedside and infusion therapy can begin immediately without the need for a confirmatory chest x-ray.

In a clinical study, 99.1% of 114 PICCs were placed at the CAJ or within +/- 1 cm using BD Tip Confirmation Technology.

†R88081-00 (BD, Salt Lake City, Utah)

 

EIFUs
Resources

About

Sherlock 3CG™ Diamond TCS compatible PICCs

 

 

Product description     

 

Item number                

PowerPICCTM Small Vein Catheter 3Fr. single lumen 

22173118

PowerPICCTM Small Vein Catheter 4Fr. double lumen

22274118

PowerPICCTM Catheter 4Fr. single lumen

22184118

PowerPICCTM Catheter 5Fr. double lumen

22285118

PowerPICCTM High Flow Catheter 5Ft. triple lumen

223751180

PowerPICCTM Catheter 6Fr. triple lumen

22386118

PowerPICC SOLO2TM  Catheter 4Fr. single lumen

22194118

PowerPICC SOLO2TM Catheter 5Ft. double lumen

222195118

PowerPICC SOLO2TM High Flow Catheter 5Fr. triple  lumen                        

223951180

PowerPICC SOLO2TM Catheter 6Fr. triple lumen

22396118

References

false
true
Sherlock 3CG+™ Tip Confirmation System BD Sherlock 3CG™ Tip Confirmation System Simultaneous View of Catheter Tip Tracking and ECG,

Catheter tip tracking and ECG confirmation are integrated on the same graphical display.

,Static ECG baseline,

Provides comparative ECG waveform for interpretation of P-wave changes and to assist in maximum P-wave identification.

,Dynamic ECG waveform,

Measures changes in P-wave morphology to allow the clinician to position the catheter tip  in proximity to the cavoatrial junction.

,Ability to maintain sterile field,

Through-drape connection allows clinician to maintain maximal barrier sterile field during placement. Probe and wireless remote allow the clinician to maintain sterility while interfacing with Sherlock 3CG+™ TCS.

,Tip Confirmation documentation,

Allows for PICC tip location to be easily documented in patient's chart or stored on the Sherlock 3CG+™ TCS System.

,Guideline Compliance,

By helping to position the PICC tip in proximity to the cavoatrial junction, the Sherlock 3CG+™ TCS System helps clinicians comply with AVA and INS guidelines for proper PICC placement.

,,

Indicated for use as an alternative method to chest X-ray and fluoroscopy for PICC tip placement confirmation in adult patients.

,,

Immediate confirmation of PICC tip position at the bedside and immediate release of the PICC line.

,,

Increases placement efficiency and reduces catheter manipulations as compared to "blind" catheter placements.

,,

Eliminates costs associated with confirmatory chest X-ray and time previously spent waiting for X-ray confirmation readings.

,,

Eliminates confirmatory chest X-ray exposure to the patient and clinician.